Customization: | Available |
---|---|
After-sales Service: | 12 monthes after shipment |
Warranty: | 12 monthes after shipment |
Still deciding? Get samples of US$ 240/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HFM510 digital display flow switch adopts the principle of thermal diffusion and is used in flow detection. The value of the regional temperature difference indicates the flow rate. Its working principle is to place a heating module and a temperature sensing module in a closed probe. The heat transfer temperature difference of the probe is closely related to the flow rate of the medium to be measured. When the medium in the pipe flows at a stable flow rate, the sensing module receives the sensing signal from the heating module is a fixed value. When the flow rate flowing through the probe changes, the thermal module will send out a temperature difference signal that changes accordingly, and the processor will output the result corresponding to the flow rate.
Measuring Range | |
Water | 1...150cm/s (Most sensitive range 1...60cm/s) |
Oil | 3...300cm/s(Most sensitive range 3...100cm/s) |
Air | 20...2000cm/s(Most sensitive range 20...700cm/s) |
Measuring Medium | Water, Oil, Air |
Withstand Voltage | 100bar |
Initialization Time | 18s |
Response Time | 1...15s, related to thermal conductivity of medium, typical value 2s |
Supply Voltage | 24VDC(18~32VDC) |
No-load current | <80mA |
Switched Output | |
Output type | 2 way PNP / 2 way NPN / 1 way Relay / 2 way PNP + Analog 4~20mA |
Load Capacity | 150mA max(PNP);1A max(relay);500Ω max(4~20mA) |
Display | |
Alarm Indication | LED(Red ) |
Status Indicator | 4 bits LCD digital tube |
Temperature | |
Operating Temp | -20~80ºC |
Medium Temp | -20~80ºC |
Storage Temp | -20~100ºC |
Material | |
Shell | SUS304 |
Probe | SUS304 |
Protection Grade | IP67 |
Wiring Method | M12 Connector |
Signal | M12×1 | Cable Output | |
Power+ | 1 | Brown | |
Power- | 3 | Blue | |
Electronic Switch 1/ Relay normally on | 4 | Black | |
Electronic Switch 2/ Relay normally closed | 2 | White | |
4~20mA/ Common port of Relay | 5 | Grey |
Two Way PNP Output | |
Two Way NPN Output | |
One Way Relay | |
Two way PNP+ Analog |
Item NO. | Type | |||||
HFM510 | Digital explicit flow switch |
|||||
Code | Thread Spec | |||||
G14 | G1/4 | |||||
G12 | G1/2 | |||||
M18 | M18*1.5 | |||||
Code | Output Signal | |||||
N | 2 way NPN output | |||||
P | 2 way PNP output | |||||
R | 1 way Relay output | |||||
C | 2 way PNP+ Analog | |||||
Code | Supply Power | |||||
V1 | 24VDC | |||||
Code | Length of the probe | |||||
L | Fill out X directly | |||||
Code | Electrical Connector | |||||
M | M12 | |||||
Yn | Cable outlet, Standard n=1 meter |
|||||
HFM510 | G12 | C | V1 | L=15 | M |