Customization: | Available |
---|---|
Type: | Protective Pressure Transmitter |
Structure Type: | Diffused Silicon |
Still deciding? Get samples of US$ 42/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HPM280 Protective Pressure Transmitter adopts high stable and reliable diffused silicon piezoresistive pressure sensor as signal measuring element. It is processed through automatic testing and laser trimming to achieve wide temperature compensation. The product has stable and reliable performance because they all pass the strict testing and ageing testing. With field digital display, it is applied to the occasion of measuring pressure in the hostile working environment. HPM280 can be widely used for pressure measurement in the fields of machinery, metallurgy, petrochemical, power, etc.
·Aluminium alloy shell, ingress protection IP65
·Field display, 4-20mADC signal output and other telecommunication signals
Measuring Medium | Liquid, Gas or Steam |
Pressure Range | -100kPa...0~1kPa...100MPa |
Overload | 1.5 times the full scale |
Pressure Type | Gauge, Absolute or Sealed Gauge |
Accuracy | ±0.25%FS(Representative); ±0.5%FS(Maximum) |
Long-term Stability | ±0.1%FS/year(Representative); ±0.2%FS/year(Maximum) |
Temperature Coefficient of Zero | ±0.03%FS/ºC(Reference 25ºC) |
Temperature Coefficient of Full Scale | ±0.03%FS/ºC(Reference 25ºC) |
Working Temp | -30~85ºC |
Storage Temp | -40~120ºC |
Supply Voltage | 24VDC(12~30V) |
Output Signal | 4~20mADC or Customization |
Output Mode | Two-wire, Three-tire |
Load Resistance | ≤(U-12)/0.02Ω |
Insulation Resistance | 100MΩ, 500VDC |
Protection of Shell | IP65 |
Electrical Connection | Dedicated Shield Cable 1.5 meters |
Housing Material | 304, 316L |
Item NO. | Type | |||||||
HPM280 | Protective Pressure Transmitter | |||||||
Pressure Range | Measuring Range | |||||||
(0~X)kPa | Fill out X directly | |||||||
Code | Output Signal | |||||||
B1 | (4~20)mA | |||||||
B2 | (0~10)mA | |||||||
B3 | (0~10)V | |||||||
B4 | (0~5)V | |||||||
B5 | (1~5)V | |||||||
B6 | (0.5~4.5)V | |||||||
Code | Thread Spec | |||||||
P1 | M20×1.5 | |||||||
P4 | G1/2 | |||||||
P17 | M27×2 | |||||||
Code | Electrical Connection | |||||||
C2 | Cable Outlet | |||||||
Code | Structure&Material | |||||||
Diaphragm | Interface | Shell | ||||||
M1 | 316L | 316L | Stainless Steel | |||||
M2 | 316L | 316L | 316L | |||||
M3 | Tantalum | Hastelloy | 316L | |||||
M4 | Titanium | Titanium | 316L | |||||
X | Other | |||||||
Code | Additional Functions | |||||||
G | Gauge Pressure(Default) | |||||||
A | Absolute Pressure | |||||||
S | Sealed Gauge Pressure | |||||||
v | Fluororubber O-Ring(Default) | |||||||
j | Buna-n O-Ring | |||||||
h | All-welded without O-Ring | |||||||
d | Explosion-proof tYPE, Exd II CT6 | |||||||
D1 | LED Display | |||||||
D2 | LCD Display | |||||||
L | atmospheric pressure measurement within 10kPa |
|||||||
W | water-proof and ventilated treatment | |||||||
HPM280 | (0~600)kPa | B1 | P1 | C2 | M1 | GvW |