Measuring Medium | Liquid, Gas, Steam |
Pressure Range | -100kPa...0~10kPa...10MPa |
Overload | 1.5 times the full scale |
Pressure Type | Gauge, Absolute or Sealed Gauge |
Accuracy | ±0.25%FS (Typical); ±0.5%FS (Maximum) |
Long-term Stability | ±0.1%FS/year (Typical); ±0.2%FS/year (Maximum) |
Temperature Coefficient of Zero | ±0.03%FS/ºC |
Temperature Coefficient of Full Scale | ±0.03%FS/ºC |
Storage Temp | -40~85ºC or -40~150ºC |
Supply Voltage | 24VDC (12~30V) |
Output Signal | 4~20mADC or other Customization |
Insulation Resistance | 100MΩ,500VDC |
Protection of Shell | IP65 |
Electrical Connection | Cable outlet, M12×1 |
Housing Material | 316L |
Cable straight out | M12*1 | Two Wires | Three Wires |
Red | 1 | Supply+ (+V) | Supply+ (+V) |
Black | 2 | Supply- (0V/+OUT) | Common (GND) |
Blue | 3 | - | Out+(+OUT) |
Item NO. | Type | |||||||
HPM760K | Clamp Hygienic Pressure Transmitter | |||||||
Pressure Range | Measuring Range | |||||||
(0~X)kPa | Fill out X directly | |||||||
Code | Output Signal | |||||||
B1 | (4~20)mA | |||||||
B3 | (0~10)V | |||||||
B4 | (0~5)V | |||||||
B5 | (1~5)V | |||||||
Code | Thread Spec | |||||||
K1 | Tri-Clamp 1-1/2″ Quick Clamp | |||||||
K2 | Tri-Clamp 2″ Quick Clamp | |||||||
K3 | DIN11851 DN25 Joint Nut | |||||||
K4 | DIN11851 DN40 Joint Nut | |||||||
K5 | SMS DN1-1/2″ Joint Nut | |||||||
K6 | SMS DN2″ Joint Nut | |||||||
Code | Electrical Connection | |||||||
C2 | Cable Outlet | |||||||
C5 | M12×1 | |||||||
Code | Structure&Material | |||||||
M2 | 316L | |||||||
Code | Additional Functions | |||||||
Y6 | Top Display | |||||||
Y7 | Dide Display | |||||||
T | High-temperature Resistance | |||||||
HPM760K | (0~40)kPa | B1 | K1 | C2 | M2 | Y6 T |