| Pressure Range | ||||||
| Rated range (Gauge,kPa) |
50 | 100 | 200 | 500 | 1000 | 2000 |
| Min range (Gauge, kPa) |
20 | 60 | 120 | 250 | 500 | 1000 |
| Overload (kPa) | 100 | 200 | 400 | 1000 | 1500 | 3500 |
| Note:The measuring unit can be converted into mmH2O@ 4ºC, inH2O@4ºC etc When m, mm, etc. are used as units, please give the density value of the measuring medium |
||||||
| Measurement Medium | |
| Medium Type | Any of various liquids compatible with contact materials |
| Output Signal/Power Supply | |
| Standard | Two wires:4~20mADC /Vs=10~30Vdc |
| Standard | Two wires:4~20mADC+HART /Vs=12~32Vdc |
| Standard | Three wires:0~5V etc /Vs=10~30Vdc |
| Standard | Four wires:Modbus-RTU/RS485 /Vs=3~8Vdc or 10~30Vdc |
| Charatistics | |
| Accurate | ±0.5%F.S.(Typical) ±0.2%F.S.(HART) * Accuracy refer to IEC 60770(nonlinear, hysteresis, repeatability) |
| Code | Position | Instruction |
| DF | Probe Housing | PVDF, density 1.78g/cm3, Shore hardness 77, suitable temperature -10 ~ 140ºC |
| PC | PVC, density 1.45g/cm3, Shore hardness 79, suitable temperature -10 ~ 70ºC | |
| PP | PP, density 0.91g/cm3, Shore hardness 72, suitable temperature -10 ~ 100ºC | |
| PTFE | PTFE, density 2.17g/cm3, Shore hardness 54 ~ 60, suitable temperature -200 ~ 260ºC | |
| M5 | Sensor | Ceramic Al2O3 96% |
| F1 | O-ring | FKM(Temperature range -20~200ºC) |
| F2 | FFKM(More anti-corrosion,temperature range -25~300°) | |
| FE | Cable | PTFE cable,outer diameter(7.2±0.2)mm |
| PU | PU cable,outer diameter(7.2±0.2)mm |
| Probe | Cable | ||||||
| Housing Material | PVC | PP | PVDF | Cable material | PTFE | PU | |
| Weight | ~480 | ~430 | ~530 | Weight(1m) | ~60 | ~50 | |
| Thread installation (W1) dimension |