High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid

Product Details
Customization: Available
Type: Thermocouple
Measuring Medium: Temperature
Still deciding? Get samples of US$ 160/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Customization from Designs
The supplier provides design based customization services
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (30)
  • High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid
  • High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid
Find Similar Products

Basic Info.

Model NO.
WR
Display Type
Display Instrument
Site Display
Not Site Display
Accuracy
0.2%FS
IP Rating
IP65
Certification
ISO9001
Customized
Customized
Sensor Type
Thermocouple
Temperature
0~1800ºC
Medium
Liquid, Gas, Steam
Protection Grade
IP65
Output Signal
Single/Double
Transport Package
Carton
Trademark
HangJia
Origin
China
HS Code
90262010
Production Capacity
50000 Pieces / Year

Product Description

Product Overview:

WR Thermocouple as the sensor for measuring temperature, often matches with display instrument, recorder and electronic regulator for use. It can directly measure the temperature of the liquid, steam and air medium from 0ºCto 1800ºC during productive process.


Features:

·Imported temperature-sensing element stable and reliable function
·High machanical strength, good pressure resistance
·Wide measuring range, high measuring accuracy


Parameters:

Temperature Range and Accuracy
Thermocouple Name Type Graduation Allowable Deviation Grade Temperature Range(ºC) Allowable Deviation(Reference side 0ºC)
Platinum rhodium30-Platinum rhodium6 WRB(WRR) B 2 Grade 600~1700 ±0.0025t
3 Grade 600~800 ±4ºC
800~1700 ±0.005t
Platinum rhodium10-platinum WRS(WRP) S 2 Grade 0~600 ±1.5ºC
600~1600 ±0.0025t
Platinum rhodium13-platinum WRR(WRQ) R 2 Grade 0~600 ±1.5ºC
600~1600 ±0.0025t
Nickel chromium-nisiloy WRK(WRN) K 2 Grade -40~333 ±2.5ºC
333~1200 ±0.0075t
Nickel chromium-Copper Nickel WRE E 2 Grade -40~333 ±2.5ºC
333~900 ±0.0075t
Copper-Copper Nickel WRT(WRC) T 2 Grade -40~133 ±1ºC
133~350 ±0.0075t
 Iron-Copper Nickel WRJ(WRF) J 2 Grade -40~+333 ±2.5ºC
333~750 ±0.0075t
Nichrosi -Nickel Silicon Magnesium WRN(WRM) N 2 Grade -40~333 ±2.5ºC
333~1200 ±0.0075t
Remark: The "t" in formula is Absolute value of measured temperature of temperature sensing element.

Thermal Response Time
When there is a step change in temperature,The time required for the output of the thermal resistance to change to 50% of the step change, It's called thermal response time, with T0.5 said.
Protective tube diameter(mm) Protective pipe material Thermal response time(s)
Φ16 High aluminum tubes/Alundum tube ≤150
Φ16 metallic conduit ≤90
Φ20 High aluminum tubes/Alundum tube ≤240
Φ20 metallic conduit ≤90
Φ25 High aluminum tubes/Alundum tube ≤360
Taper protective tube metallic conduit ≤150

Thermocouple Nominal Pressure
Generally refers to the external pressure (static pressure) that the protective tube can withstand at this working temperature.The allowable nominal pressure is not only related to the material, diameter and wall thickness of the protective tube, but also to its structure, installation method, placement depth and the flow rate and type of the measured medium. 


Structure Drawings:

High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid


Ordering Guide:
 
Item NO. Type  
WR Industrial
 Thermocouple
  Code Thermocouple Type  
Graduation Type
R B Platinum rhodium30-Platinum rhodium6
P S Platinum rhodium10-platinum
Q R Platinum rhodium13-platinum
N K Nickel chromium-nisiloy
E E Nickel chromium-Copper Nickel
F J Iron-Copper Nickel
C T Copper-Copper Nickel
M N Nichrosi -Nickel Silicon Magnesium
  Code Output Signal  
N/A Single
2 Double
  Code Installment Way  
1 No fixing device
2 Fixed thread
3 Flexible Flange
4 Fixed Flange
  Code Junction Box  
1 Simple Type
2 splash-proof
3 Water proof
4 explosion-proof Type
  Code Diameter of Protective Tube  
0 16mm
1 20mm
2 16mm Bauxite tube
3 20mm Bauxite tube
4 25mm Double protective tube
  Code Protective pipe material
S4 SUS304 (suitable for KNEJT)
S6 SUS316L (suitable for KNEJT)
CT1 Corundum (suitable for SRB)
CT2 Bauxite (suitable for KNSRB)
  Code Customization
N Integrated CNC, No welding
l l= Insertion depth(mm)
L L=Chief protective pipe (mm)
T Temperature T=(0,t)
For Example:WRN-230-S4 l=350 L=500 T=(0~800)ºC


Related Products:

High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid


High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid

High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid
High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid


Certification:
High Temperature S/R/B Type Platinum Rhodium Thermocouple For Gas Air Liquid




FAQ:

1.    Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on sensor for 10 years.

2.    Q: What's your quality control system?
        A: MC, ISO9001, CE Certificated.

3.    Q: What is the warranty of your products?
        A: Our warranty time is 18 months after shipment.
 
4.     Q: What is lead time of your product?
         A: Normally, our factory lead time is within 10~15 working days for products without customization. You can also check lead time detail with our sales depending on different items.
 
5.     Q: Do you provide customized products?
         A: Yes, we can laser mark your logo on products; OEM and ODM customization are welcomed.
 
6.     Q: What is your MOQ?
        A: We have no MOQ limit, small quantity order is acceptable.
 
7.      Q: What's the transport?                                                              
        A: Express such as DHL, FedEx, TNT, UPS for freight prepaid; and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by Sea.
 
8.      Q: What is your terms of payment ?
           A: We could accept T/T, Paypal, WU.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier