Customization: | Available |
---|---|
Type: | Piezoresistive Pressure Sensor |
Component: | SemiConductor Type |
Still deciding? Get samples of US$ 64/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
·High accuracy, all stainless steel structure
·polarity reversal protection ,overcurrent and overvoltage protection, meet EMI protection requirements
·Wide pressure range, available to measure absolute pressure,gauge pressure and sealed gauge pressure
·Ingress protection IP65
·Diverse structures, easy installation and use, wide universality
·Strong anti-jamming, long term stability
·Explosion-proof mark: Ex ia IIC T6 Ga (for 24VDC power supply, 4-20mA output)
Basic safety parameters: Ui:28 VDC Ii:93 mA Pi: 0.65W Ci: 0.04μF Li: 0
Measuring Medium | Liquid, Gas or Steam |
Pressure Range(gauge) | -100kPa…0~2kPa…100MPa |
Overload | 1.5 times pressure range of full scale |
Pressure Type | Gauge, Absolute or Sealed Gauge |
Accuracy | ±0.5%FS, ±0.2%FS or ±0.1%FS |
Long-term Stability | ±0.25%FS/year, ±0.2%FS/year, or ±0.1%FS/year |
Temperature Coefficient of Zero | ±1.0%FS(Reference 25ºC) |
Temperature Coefficient of Full Scale | ±1.0%FS/(Reference 25ºC) |
Working Temperature | -40~60ºC |
Storage Temperature | -40~85ºC |
Supply Voltage | 24VDC(12~28VDC) |
Output Signal | Two-wire 4~20mADC |
Protection of Shell | IP65 for DIN43650 connection; IP66 for M12x1 and IP67 for cable outlet |
Electrical Connection | DIN43650 or M12×1 or Cable Outlet |
Hirschman/DIN43650 electronical connection | M12x1 with clamps | ||||||||
M12x1 with flat film thread | Cable outlet | ||||||||
M20x1.5 thread | G1/2 thread | G1/2 flat film thread | M20x1.5 flat film thread | M20x1.5 thread with cooling fins |
IP68 submercible/Ex ia IIC T6 Ga Level transmitter HPM410W(click) |
Ex db IIC T6 Gb Pressure transmitter HPM288(click) |
Ex d II C T4~T6 Gb Differential Pressure transmitter HPM81(click) |