Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Task: | Program |
| Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency


| Input | 2-wire or 3-wire RTD, TC (To be determined when ordering, or set using a handheld PCA programmer) |
| Output | 4~20mA,0~10mA, 0~20mA,1~5V,0~5V |
| Output load | 4~20mA,0~10mA, 0~20mA RL≤400Ω, 1~5V,0~5V RL≥250KΩ |
| Power supply | DC20~32V |
| Power consumption | ≤1W with One way in, one way out ≤1.4W with One way in, two way out Or two way in, two way out |
| Insulation resistance (between output/output/power supply) | ≥100MΩ(500VDC) |
| Dielectric strength (between output/output/power supply) | 1500Vrms(1min, no sparks) |
| Ambient temperature | -10~50ºC(No condensation, no icing) |
| Relative humidity | 25%~85%RH |
| Storage temperature | -10~60ºC |
| Relative humidity | 25%~85%RH |
| Storage temperature | -20~60ºC |
| Temperature drift | 0.0075%FS/ºC |
| Mounting method | 35mm DIN rail installation |
| Mounting size | 13*108*121.2mm(width*height*depth) |
| HDM22- | Channal one/two | Channal one/two | ||||
| Input | ||||||
| Code | Index(measuring range) | |||||
| 00 | Thermocouple B (400~1800ºC) | |||||
| 01 | Thermocouple S (0~1600ºC) | |||||
| 02 | Thermocouple K(0~1300ºC) | |||||
| 03 | Thermocouple E (0~1000ºC) | |||||
| 04 | Thermocouple T (-199.9~400.0ºC) | |||||
| 05 | Thermocouple J (0~1200ºC) | |||||
| 06 | Thermocouple R (0~1600ºC) | |||||
| 07 | Thermocouple N (0~1300ºC) | |||||
| 08 | F2 (700~2000ºC) | |||||
| 09 | Thermal resistor Wre3-25 (0~2300ºC) | |||||
| 10 | Thermal resistor Wre5-26(0~2300ºC) | |||||
| 11 | Thermal resistor Cu50(-50.0~150.0ºC) | |||||
| 12 | Thermal resistor Cu53(-50.0~150.0ºC) | |||||
| 13 | Thermal resistor Cu100(-50.0~150.0ºC) | |||||
| 14 | Thermal resistor Pt100(-199.9~650.0ºC) | |||||
| 15 | Thermal resistor BA1(-199.9~600.0ºC) | |||||
| 16 | Thermal resistor BA2(-199.9~600.0ºC) | |||||
| X | Select when channel II has no input | |||||
| Output | ||||||
| Code | Type(Load resistance RL) | |||||
| X | Without | |||||
| 0 | 4~20mA | |||||
| 1 | 1~5V | |||||
| 2 | 0~10mA | |||||
| 3 | 0~5V | |||||
| 4 | 0~20mA | |||||
| Power supply | ||||||
| D | DC20~32V | |||||
| PCA Handheld Programmer is suitable for parameter configuration programming of HTM22 intelligent isolators, safety barriers and power transmitters, and can view measured values and output values in real time. | ![]() |
![]() |

1. Q: Are you manufacturer or trading company?