Customization: | Available |
---|---|
Type: | Thread connection |
Measuring Medium: | Liquid Gas Steam |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Pressure Range | -100kPa…0~2kPa…25MPa (gauge pressure) 0~10kPa…10MPa (absolute pressure) |
Temperature Range | -40~100ºC Note: Supports customized intermediate range, such as 0~80ºC, etc. |
Measuring Medium | Various liquids, gases and various compatible with contact materials |
Output Signal/Power Supply (1) | Pressure:2-wire 4~20mADC/ Vs=10~30 VDC Temperature:3-wire PT100/PT1000 |
Output Signal/Power Supply (2) | Pressure:2-wire 4~20mADC/ Vs=10~30 VDC Temperature:2-wire 4~20mADC/ Vs=10~30 VDC |
Output Signal/Power Supply (3) | Pressure:3-wire 0~5VDC / Vs=8.5~30 VDC Temperature:3-wire 0~5VDC / Vs=8.5~30 VDC |
Output Signal/Power Supply (4) | Pressure:3-wire 0~10VDC / Vs=12~30 VDC Temperature:3-wire 0~10VDC / Vs=12~30 VDC |
Output Signal/Power Supply (5) | 4-wire Modbus-RTU/RS485 / Vs=10~30 VDC(Normal) / Vs=3.1~8 VDC (battery supply, low power consumption mode) |
Accuracy | ±0.5%FS @30ºC(pressure measure, typical) ±0.25%FS @30ºC(pressure measure, improved) ±0.1%FS @30ºC(pressure measure, excellent) ±0.4ºC (temperature measure) |
Long-term Stability | ±0.25%FS/year (pressure measure, 0.5G). ±0.2%FS/year (pressure measure, 0.25G). ±0.1%FS/year (pressure measure, 0.1G). ±0.1%FS/year(temperature measure); |
*Accuracy according to IEC 60770 (non-linearity, hysteresis, repeatability) |