Customization: | Available |
---|---|
Type: | Protective Pressure Transmitter |
Component: | SemiConductor Type |
Still deciding? Get samples of US$ 75/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring range (Gauge pressure) | -100kPa…0~0kPa…100MPa |
Measuring range (Absolute pressure) |
0~0kPa…10MPa |
Overload | 1.5 times of full scale |
Medium type | Various liquids compatible with contact materials |
Output signal | RS485 |
Power supply | Vs=3.1~8VDC (lithium-ion battery inside ER14250,3.6V 1200mAh) Vs=5VDC (External power supply supported) Vs=24VDC (External power supply) |
Standby current | <20uA |
Date collection cycle | 0~65535 seconds |
Power Consumption | About 200uA with data collection cycle as 1s About 70uA with data collection cycle as 3s About 50uA with data collection cycle as 5s. … Note: Longer data collection cycle, lower consumption |
Model No. | Type |
|
|||||
HPM240L | Low consumption pressure transmitter | ||||||
Pressure range | Measuring range | ||||||
(0~X)MPa | X is the upper range limit | ||||||
Code | Pressure connection | ||||||
P1 | M20×1.5 male | ||||||
P4 | G1/2 male | ||||||
Code | Electrical connection | ||||||
C9 | Cable gland, with terminals in housing | ||||||
Code | Housing material | ||||||
Y1 | cast aluminium alloy | ||||||
Code | Sensor | ||||||
M1 | Silicon piezoresistive isolation diaphragm | ||||||
Code | Additional functions | ||||||
G | Gauge pressure(default) | ||||||
A | Absolute pressure | ||||||
QF | Factory report | ||||||
e.g.:HPM240L | (0~2.5)MPa | P1 | C9 | Y1 | M1 | G |