DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size

Product Details
Customization: Available
Task: Program
Structure: Combination
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Customization from Designs
The supplier provides design based customization services
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (30)
  • DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
  • DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
  • DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
  • DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
  • DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
  • DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
Find Similar Products
  • Overview
  • Product Features
  • Dimension (Unit:mm)
  • Wiring
  • Product Parameters
  • Ordering Guide
  • Other Supporting Equipment
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
HTM22
Mathematical Model
Linear
Signal
Continuous
Function
Automatic Control, Protection, Monitoring
Certification
ISO9001
Condition
New
Customized
Customized
Material
Plastic housing
Power Supply
DC20~32V
Input
2-wire or 3-wire RTD, TC
output
4~20mA,0~10mA, 0~20mA,1~5V,0~5V
Output load
4~20mA,0~10mA, 0~20mA RL≤400Ω, 1~5V,0~5V
Transmission accuracy(20ºC)
0.2%FS±1 bit
Min resolution
0.1ºC
Internal cold junction temperature compe
Internal cold junction temperature compensation ra
Response time
Reach 90% of final value within 50ms
Transport Package
Carton
Trademark
HIGHJOIN
Origin
China
HS Code
90262010
Production Capacity
50000 Pieces / Year

Product Description

HTM22 temperature transmitter converts the thermal resistor or thermocouple signal on site into a DC signal that is linear with the temperature and outputs it to the control system after isolation and amplification.

When used as a thermocouple temperature transmitter, it has the function of automatic cold end temperature compensation. The parameters can be modified using the matching host computer software. It can be used in conjunction with unit combination instruments and DCS, PLC and other systems to provide on-site instrument signal isolation, signal conversion, signal distribution, signal processing, etc., thereby improving the anti-interference ability of the industrial production process automatic control system and ensuring the stability and reliability of the system. This product variety is divided into one-input and one-output, one-input and two-output, and two-input and two-output, and the input and output are magnetically isolated.

Product Features

 
  • Single channel, dual channel
  • Two or three-wire thermal resistor, thermocouple input
  • Analog output
  • Input/output/power supply magnetic isolation
  • Transmission accuracy (20ºC): 0.2%FS ± 1 bit
  • 17 types of input types, input and output ranges and other parameters can be set and viewed through the PCA handheld programmer
  • Short response time, thin thickness, low power consumption
  • Plug-in terminals for easy installation and maintenance
  • Standard 35mm DIN rail card installationDIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size

Dimension (Unit:mm)

DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size

Wiring

DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size

Product Parameters

Input 2-wire or 3-wire RTD, TC (To be determined when ordering, or set using a handheld PCA programmer)
Output 4~20mA,0~10mA, 0~20mA,1~5V,0~5V
Output load 4~20mA,0~10mA, 0~20mA RL400Ω,
1~5V,0~5V RL250KΩ
Power supply DC20~32V
Power consumption 1W with One way in, one way out
1.4W with One way in, two way out Or two way in, two way out
Insulation resistance (between output/output/power supply) 100MΩ(500VDC)
Dielectric strength (between output/output/power supply) 1500Vrms(1min, no sparks)
Ambient temperature -10~50ºC(No condensation, no icing)
Relative humidity 25%~85%RH
Storage temperature -10~60ºC
Relative humidity 25%~85%RH
Storage temperature -20~60ºC
Temperature drift 0.0075%FS/ºC
Mounting method 35mm DIN rail installation
Mounting size 13*108*121.2mm(width*height*depth)
DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
 

Ordering Guide

DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
HDM22- Channal one/two Channal one/two  
  Input    
Code Index(measuring range)
00 Thermocouple B (400~1800ºC)
01 Thermocouple S (0~1600ºC)
02 Thermocouple K(0~1300ºC)
03 Thermocouple E (0~1000ºC)
04 Thermocouple T (-199.9~400.0ºC)
05 Thermocouple J (0~1200ºC)
06 Thermocouple R (0~1600ºC)
07 Thermocouple N (0~1300ºC)
08 F2 (700~2000ºC)
09 Thermal resistor Wre3-25 (0~2300ºC)
10 Thermal resistor Wre5-26(0~2300ºC)
11 Thermal resistor Cu50(-50.0~150.0ºC)
12 Thermal resistor Cu53(-50.0~150.0ºC)
13 Thermal resistor Cu100(-50.0~150.0ºC)
14 Thermal resistor Pt100(-199.9~650.0ºC)
15 Thermal resistor BA1(-199.9~600.0ºC)
16 Thermal resistor BA2(-199.9~600.0ºC)
X Select when channel II has no input
  Output
Code Type(Load resistance RL)
X Without
0 4~20mA
1 1~5V
2 0~10mA
3 0~5V
4 0~20mA
  Power supply  
D DC20~32V

Other Supporting Equipment

DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size PCA Handheld Programmer is suitable for parameter configuration programming of HTM22 intelligent isolators, safety barriers and power transmitters, and can view measured values and output values in real time.
 

Company Profile

DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size

DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size
DIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin sizeDIN rail mounting RTD PT input analog 4-20ma 0-10V output Temperature transmitter thin size

FAQ

1.    Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on sensor for 10 years.

2.    Q: What's your quality control system?
        A: MC, ISO9001, CE Certificated.

3.    Q: What is the warranty of your products?
        A: Our warranty time is 18 months after shipment.

 
4.     Q: What is lead time of your product?
         A: Normally, our factory lead time is within 10~15 working days for products without customization. You can also check lead time detail with our sales depending on different items.
 
5.     Q: Do you provide customized products?
         A: Yes, we can laser mark your logo on products; OEM and ODM customization are welcomed.
 
6.     Q: What is your MOQ?
        A: We have no MOQ limit, small quantity order is acceptable.
 
7.     Q: What's the transport?                                                              
        A: Express such as DHL, FedEx, TNT, UPS for freight prepaid; and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by Sea.
 
8.      Q: What is your terms of payment ?
           A: We could accept T/T, Paypal, WU.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now