Industrial Thermal Cu50 Resistance Temperature Sensor

Product Details
Customization: Available
Type: Thermal Resistance
Measuring Medium: Temperature
Still deciding? Get samples of US$ 22/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Customization from Designs
The supplier provides design based customization services
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Industrial Thermal Cu50 Resistance Temperature Sensor
  • Industrial Thermal Cu50 Resistance Temperature Sensor
Find Similar Products

Basic Info.

Model NO.
WZ
Display Type
Display Instrument
Site Display
Not Site Display
Accuracy
0.2%FS
IP Rating
IP65
Certification
ISO9001
Customized
Customized
Sensor Type
Thermal Resistance
Temperature
-200~500ºC
Medium
Liquid, Gas, Steam, Solid
Transport Package
Carton
Trademark
HangJia
Origin
China
HS Code
90262010
Production Capacity
50000 Pieces / Year

Product Description

Product Overview:

WZ Thermal Resistance as the sensor for measuring temperature, often matches with display instrument, recorder and electronic regulator for use. It can directly measure the surface temperature of the liquid, steam and air medium from -200ºCto 500ºC as well as the surface temperature of solid during productive process.


Features:

·Imported temperature-sensing element stable and reliable function
·High machanical strength, good pressure resistance
·High measuring accuracy
·Compensating wire needless, convenient and economical


Parameters:

Temperature Range and Accuracy
Thermal resistance Type Thermal Resistance Allowable deviationt ºC
WZP Type platinum resistor Pt100 B Grade ±(0.3 or+0.005t)
A Grade ±(0.15 or+0.002t)
WZC Type Copper Resistance Cu50 -50~100ºC ±(0.30+6.0×10-3t)
Remark: The "t" in formula is Absolute value of measured temperature of temperature sensing element.

Thermal Response Time
When there is a step change in temperature,The time required for the output of the thermal resistance to change to 50% of the step change, It's called thermal response time, with T0.5 said.
Protective tube diameter(mm)  Protective tube Material Thermal response time t0.5 (s)
Platinum
thermal resistance
Φ12 1Cr18Ni9Ti 30~90
Φ16 30~90
Taper protective tube 90~180
Copper thermal resistance Φ12 1Cr18Ni9Ti <180

Thermal resistance Nominal Pressure

Generally refers to the external pressure (static pressure) that the protective tube can withstand at this working temperature.The allowable nominal pressure is not only related to the material, diameter and wall thickness of the protective tube, but also to its structure, installation method, placement depth and the flow rate and type of the measured medium.

Thermal resistance Minimum Placed-depth

lmin=l +15D
lmin-Minimum Available Placed-depth
L -Temperature sensing element length
D-Outer diameter of protective pipe

Insulation Resistance

The test voltage of insulation resistance at room temperature can be 10 ~ 100V dc arbitrary value, the ambient temperature in the range of 15 ~ 35ºC, the relative humidity should not be more than 80%.Cold insulation resistance shall be not less than 100 m Ω.


Structure Drawings:


Industrial Thermal Cu50 Resistance Temperature Sensor


Ordering Guide:
 
Item NO. Type  
WZ Thermal 
Resistance
  Code Type of
Thermal 
Resistance
 
P Pt100
C Cu50
  Code Output Signal  
N/A Singal
2 Double
  Code Installment Way  
1 No fixing device
2 Fixed thread
3 Flexible Flange
4 Fixed Flange
  Code Junction Box  
1 Simple Type
2 splash-proof
3 Water proof
4 explosion-proof Type
7 Aviation Plug in
  Code Diameter of 
Protective Tube
 
0 16mm
1 12mm
Other Mark with Words
  Code Material of 
Protective
 Tube
 
S4 SUS304
S6 SUS316L
  Code Type of 
 Measuring 
Terminal
 
2 Two-wire
3 Three-wire
  Code Customizatioon
N Integration CNC, No Welding
l l=Insertion Depth(mm)
L L=Length of Protective Tube(mm)
T Temperature Range T=(t1,t2)
For ExampleWZP2-230-S4-3 l=100 L=250 T=(0~300)ºC


Related Products:

Industrial Thermal Cu50 Resistance Temperature Sensor


Industrial Thermal Cu50 Resistance Temperature Sensor

Industrial Thermal Cu50 Resistance Temperature Sensor
Industrial Thermal Cu50 Resistance Temperature Sensor


Certification:
Industrial Thermal Cu50 Resistance Temperature Sensor




FAQ:

1.    Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on sensor for 10 years.

2.    Q: What's your quality control system?
        A: MC, ISO9001, CE Certificated.

3.    Q: What is the warranty of your products?
        A: Our warranty time is 18 months after shipment.
 
4.     Q: What is lead time of your product?
         A: Normally, our factory lead time is within 10~15 working days for products without customization. You can also check lead time detail with our sales depending on different items.
 
5.     Q: Do you provide customized products?
         A: Yes, we can laser mark your logo on products; OEM and ODM customization are welcomed.
 
6.     Q: What is your MOQ?
        A: We have no MOQ limit, small quantity order is acceptable.
 
7.      Q: What's the transport?                                                              
        A: Express such as DHL, FedEx, TNT, UPS for freight prepaid; and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by Sea.
 
8.      Q: What is your terms of payment ?
           A: We could accept T/T, Paypal, WU.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier