• LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output
  • LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output
  • LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output
  • LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output
  • LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output
  • LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output

LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output

Type: Temperature Transmitter Moduel
Measuring Medium: Liquid Gas Steam
Display Type: LCD
Site Display: Site Display
Accuracy: 0.1%F.S.
IP Rating: IP65
Samples:
US$ 55/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Jiangsu, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Customization from Designs
The supplier provides design based customization services
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (30)

Basic Info.

Model NO.
HT218M
Certification
ISO9001
Customized
Customized
Can equiped with
RTD(PT100, CU50), TC(B,E,J,K...)
Pressure Reference
24VDC
Supply Voltage
16-40VDC
Working Temp
-40~80ºC
Storage Temp
-40~100ºC
Output signal
4~20mA, RS485, HART
Load resistance
RL≤(Ue-14)/0.021
limit overflow alarm output current
IH=21mA, IL=3.8mA
Transport Package
Carton
Trademark
HIGHJOIN
Origin
China
HS Code
90262010
Production Capacity
50000 Pieces / Year

Product Description

Product Overview:
 
HT218M  LCD isolation intelligent temperature transmitter is used for RTD, thermocouple (TC), resistance  (Ω),   signal  input,  two-wire  system  4-20mA  analog  output,  and  the configuration is via RS485 (MODBUS RTU protocol) or HART protocol.


Features:
  • Input signal supports 2 RTDs, 10 thermocouples
  • Input signal is fully switchable
  • 4~20mA output, RS485,HART optional
  • Thermocouple cold end compensation
  • Response time≤700mS
  • Input and output isolation, good anti-interference effect
 
Parameters:
Input signal RTDs and thermocouples
Cold-end compensation temperature range -20~70ºC
Compensation accuracy ±1ºC
Output signal 4~20mA, or 4~20mA plus HART protocol
Load resistance RL≤(Ue- 14)/0.021
Overflow alarm output current
at the upper and lower limits.
IH=21mA, IL=3.8mA
Power supply  DC16~40V
Temperature drift 0.015%FS/ºC
Response time reaches 90% of the final scale within 1s
Ambient temperature in use -20~70ºC
Dielectric strength 1500Vrms(in 1 min)
electrical insulation resistance >=100MΩ (500VDC)
 
Input type and transmission accuracy    
Input  Code Type Measuring temperature  Range Min. measuring range Conversion accuracy
(whichever is greater)
RTD Pt100 Pt100 -200.0~850.0ºC 20ºC ±0.1%FS or ±0.2ºC
Cu50 Cu50 -50.0~150.0ºC 20ºC ±0.1%FS or ±0.2ºC
TC(thermocouples) TC-B B 400~1800ºC 500ºC ±0.1%FS or ±1.5ºC
TC-E E -100~1000ºC 50ºC ±0.1%FS or ±0.5ºC
TC-J J -100~1200ºC 50ºC ±0.1%FS or ±0.5ºC
TC-K K -180~1372ºC 50ºC ±0.1%FS or ±0.5ºC
TC-N N -180~1300ºC 50ºC ±0.1%FS or ±0.5ºC
TC-R R -50~1768ºC 500ºC ±0.1%FS or ±1.5ºC
TC-S S -50~1768ºC 500ºC ±0.1%FS or ±1.5ºC
TC-t T -200~400ºC 50ºC ±0.1%FS or ±0.5ºC
Note:
1. The above accuracy data is tested under the condition of ambient temperature of 20ºC±2ºC.
2. The output accuracy "%" is relative to the set range.
3. Thermocouple measurement also need to add the cold end compensation error, internal cold end compensation error ≤ ± 1 ºC.
Structure Drawing:
 LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 outputWiring:
LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output

Application:
LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 outputRelated Products:
LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 outputLCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output
LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 outputCertification:
LCD display smart Temperature transmitter which can equip PT100, PT1000, RTD with 4-20ma RS485 output
FAQ:

1.    Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on sensor for 10 years.

2.    Q: What's your quality control system?
        A: MC, ISO9001, CE Certificated.

3.    Q: What is the warranty of your products?
        A: Our warranty time is 18 months after shipment.
 
4.     Q: What is lead time of your product?
         A: Normally, our factory lead time is within 10~15 working days for products without customization. You can also check lead time detail with our sales depending on different items.
 
5.     Q: Do you provide customized products?
         A: Yes, we can laser mark your logo on products; OEM and ODM customization are welcomed.
 
6.     Q: What is your MOQ?
        A: We have no MOQ limit, small quantity order is acceptable.
 
7.      Q: What's the transport?                                                              
        A: Express such as DHL, FedEx, TNT, UPS for freight prepaid; and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by Sea.
 
8.      Q: What is your terms of payment ?
           A: We could accept T/T, Paypal, WU.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now