Customization: | Available |
---|---|
Type: | Negative Pressure Transmitter |
Structure Type: | Ceramic Pressure Transmitter |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring Range | |||||||||||||
Absolute (kPa) |
Rated pressure | 0.2 | 0.5 | 1 | 2 | 5 | 10 | 20 | 100 | ||||
Overload | 200 | 200 | 200 | 200 | 400 | 400 | 600 | 1000 | |||||
Absolute (Torr) |
Rated pressure | 2 | 5 | 10 | 20 | 50 | 100 | 200 | 1000 | ||||
Overload | 2000 | 2000 | 2000 | 2000 | 4000 | 4000 | 6000 | 10000 | |||||
Absolute (mbar) |
Rated pressure | 2 | 5 | 10 | 20 | 50 | 100 | 200 | 1000 | ||||
Overload | 2000 | 2000 | 2000 | 2000 | 4000 | 4000 | 6000 | 10000 | |||||
Note: For other measuring ranges, please contact us. | |||||||||||||
Measuring Medium | |||||||||||||
Type | Various gases compatible with contact materials | ||||||||||||
Output Signal/Power Supply | |||||||||||||
Standard | 4~20mA / Vs=10~30 VDC | ||||||||||||
Standard | 0~5VDC /Vs=8.5~30 VDC | ||||||||||||
Standard | 0~10VDC /Vs=12~30 VDC | ||||||||||||
Standard | RS485 /Vs=10~30 VDC | ||||||||||||
Performance | |||||||||||||
Accuracy | ±0.1%FS (20kPa,100kPa) ±0.25%FS (5kPa,10kPa) ±0.5%FS (500Pa,1kPa,2KPa) ±1.5%FS (200Pa) |
||||||||||||
Long-term stability | ±0.50%FS/year, ≤1kPa ±0.25%FS/year, >1kPa |
Ordering Code | Part | Materials |
S4 | Pressure Interface | SS304 |
S6 | SS316L | |
PE | PEEK | |
M6 | Sensor | Ceramic Al2O3 99.9% |
FK | O-Ring | FKM Fluoro rubber |
NB | NBR Nitrile |