| Outline Dimension | Hole Dimension | Outline Dimension | Hole Dimension |
| 160*80mm (Horizontal type) |
152*76mm | 48*96mm (Vertical Type) |
45*92mm |
| 80*160mm (Vertical Type) |
76*152mm | 72*72mm (Quadrate Type) |
68*68mm |
| 96*96mm (Quadrate Type) |
92*92mm | 48*48mm (Quadrate Type) |
45*45mm |
| 96*48mm (Horizontal type) |
92*45mm |
| 1. Specification | 2. Graduation Input | ||
| Code | Width*Height*Depth | Code | Graduation (Measuring Range) |
| A | 160*80*110mm (Horizontal type) | 0 | Thermocouple B(400~1800ºC) |
| B | 80*160*110mm (Vertical Type) | 1 | Thermocouple S(0~1600ºC) |
| C | 96*96*110mm (Quadrate Type) | 2 | Thermocouple K(0~1300ºC) |
| D | 96*48*110mm (Horizontal type) | 3 | Thermocouple E(0~1000ºC) |
| E | 48*96*110mm (Vertical Type) | 4 | Thermocouple T(-200.0~400.0ºC) |
| F | 72*72*110mm (Quadrate Type) | 5 | Thermocouple J(0~1200ºC) |
| H | 48*48*110mm (Quadrate Type) | 6 | Thermocouple R(0~1600ºC) |
| 3. OUTPUT | 7 | Thermocouple N(0~1300ºC) | |
| Code | Output Type ( load resistance RL) | 8 | F2(700~2000ºC) |
| X | No output | 9 | Thermocouple Wre3-25(0~2300ºC) |
| 0 | 4-20mA(RL≤500Ω) | 10 | Thermocouple Wre5-26(0~2300ºC) |
| 1 | 1-5V(RL≥250KΩ) | 11 | Thermal Resistance CU50(-50.0~150.0ºC) |
| 2 | 0-10mA(RL≤1KΩ) | 12 | Thermal Resistance CU53(-50.0~150.0ºC) |
| 3 | 0-5V(RL≥250KΩ) | 13 | Thermal Resistance CU100(-50.0~150.0ºC) |
| 4 | 0-20mA(RL≤500Ω) | 14 | Thermal Resistance PT100(-200.0~650.0ºC) |
| 5 | 0-10V(RL≥4KΩ) | 15 | Thermal Resistance BA1(-200.0.0~600.0ºC) |
| D1 | RS485 communication interface (Modbus RTU) | 16 | Thermal Resistance BA2(-200.0~600.0ºC) |
| 4. Alarm (Relay contact output)(See Note) | 17 | Linear Resistance 0~1KΩ(-1999~9999) | |
| Code | Alarm Ways | 18 | Remote Resistance 0-350Ω (-1999~9999) |
| X | No Output | 19 | Remote Resistance 30-350Ω (-1999~9999) |
| 1 | 1 way Alarm | 20 | 0~20mV (-1999~9999) |
| 2 | 2 way Alarm | 21 | 0~40mV (-1999~9999) |
| 5. Power Output | 22 | 0~100mV (-1999~9999) | |
| Code | Power Output (Output Voltage) | 23 | Internal retention |
| X | No output | 24 | Internal retention |
| P | Power Output(Load Current≤30mA) | 25 | 0~20mA (-1999~9999) |
| Such as "P(24)"says Power Output24V. | 26 | 0~10mA (-1999~9999) | |
| 6.Power Supply | 27 | 4~20mA (-1999~9999) | |
| Code | Voltage Range | 28 | 0~5V (-1999~9999) |
| A | AC/DC 100-240V (AC/50-60Hz) | 29 | 1~5V (-1999~9999) |
| D | DC 12-36V | 30 | Internal retention |
| 7. Remark | 31 | 0~10V (-1999~9999) | |
| No remarks can be omitted | 32 | 0~10mA Square Root (-1999~9999) | |
| 33 | 4~20mA Square Root (-1999~9999) | ||
| 34 | 0~5V Square Root (-1999~9999) | ||
| 35 | 1~5V Square Root (-1999~9999) | ||
| 55 | All Switch | ||