Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Type: | Negative Pressure Transmitter |
| Structure Type: | Diffused Silicon Pressure Transmitter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Measuring Range (Gauge) | -100kPa…0~10kPa…60MPa |
Measuring Range (Absolute) | 0~20kPa…60MPa |
Overload | 1.5
times the full scale |
Measuring Medium | Various
liquids and gases compatible with contact materials |
Output Signal (option 1) | 2-wire 4~20mA/ Vs=8~30V |
Output Signal (option 2) | 2-wire 4~20mA+HART / Vs=12~32V |
Output Signal (option 3) | 3-wire 0~10V/ Vs=12~30V |
Accuracy* | ±0.5%FS@25℃ ±0.2%FS@25℃ |
Long-term Stability | ±0.25%FS/year(0.5%FS accuracy) ±0.2%FS/year(0.2%FS accuracy) |
*Accuracy conforms to IEC 60770 (non-linearity, hysteresis, repeatability) | |
Compensation Temperature Range | 0~70℃ (0.5%FS accuracy ) -10~80℃ (0.2%FS accuracy ) Note: For measuring range ≤20kPa, please consult. |
Zero-point Temperature Drift | ±1.0%FS
Reference 25℃, within the temperature compensation
range (temperature drift of ±2.0%FS for 10kPa range, 0~60℃) |
Full-scale Temperature Drift | ±1.0%FS
Reference 25℃, within the temperature compensation
range (temperature drift of ±2.0%FS for 10kPa range, 0~60℃) |
Medium Temperature | -40~100℃ |
Ambient Temperature | -20~80℃ |
Storage Temperature | -20~80℃ |
Protection Rating | IP66, M12x1 (ordering code C5) |







Model | Type | ||||||||
HPM260 | Pressure Transmitter | ||||||||
Pressure Range | Measuring Range | ||||||||
(X1~X2)MPa | X1 is the lower limit X2 is the upper limit | ||||||||
Code | Output Signal | ||||||||
B1 | (4~20)mA | ||||||||
B3 | (0~10)V | ||||||||
B8 | HART | ||||||||
Code | Thread Spec | ||||||||
P1 | M20×1.5 male | ||||||||
G12 | G1/2 male | ||||||||
G14 | G1/4 male | ||||||||
Code | Electrical Connection | ||||||||
C5 | M12×1 | ||||||||
C5X | M12×1 with cable | ||||||||
Code | Shell Material | ||||||||
S4 | SS304 | ||||||||
S6 | SS316L | ||||||||
Code | Process Connection | ||||||||
S4 | 304 | ||||||||
S6 | 316L | ||||||||
Code | Sensor | ||||||||
M1 | SS316L (by default) | ||||||||
M2 | Titanium diaphragm TA1 and titanium shell TC4 | ||||||||
M3 | Tantalum film Ta | ||||||||
M4 | Hastelloy C-276 | ||||||||
Code | Others | ||||||||
G | Gauge pressure(by default) | ||||||||
S | Sealed gauge | ||||||||
A | Absolute | ||||||||
Y6 | Top Display | ||||||||
Y7 | Side Display | ||||||||
J5 | 0.5%FS Accuracy(by default) | ||||||||
J2 | 0.2%FS Accuracy | ||||||||
QF | With factory report | ||||||||
Others requests | |||||||||
Eg: HPM260 | (0~1)MPa | B1 | P1 | C5X | S4 | S4 | M1 | G Y7 J5 QF | |